Pollution-free
- full automatic clean generation-of-gas equipment.
Prolonged continuation operation is possible - Maintenance-free
Generation-of-gas equipment of the in-situ type which
supplies the clean hydrogen gas which impurities do
not mix by adoption of ion exchange membrane type water
electrolysis |
|
 |
 |
 |
 |
 |
 |
 |
For hydrogen addition
of various chemical reactions |
 |
High purity gas for various
burning.
- A marking pretreatment of IC and electronic products
- Metalworking, such as a false tooth and a jewelry
craft
- Plastic melting processing |
 |
Fuel cell, other fuel |
 |
For functional water
(hydrogen water) manufacture |
|
 |
 |
 |
 |
 |
 |
 |
The High Pressure
Gas Safety Law in Japan is not applied.
Since gas supply power is 0.1~0.3MPa, The High Pressure
Gas Safety Law in Japan is not applied to it."
|
 |
Only pure water
is needed as material.
"If there are even a power supply and pure water,
supply of gas is possible anywhere. Therefore, a worker
is free from conveyance and exchange of a cylinder." |
 |
High safety
There is very few of gas staying within equipment, so
the equipmewnt operation is excellent in safety. |
 |
Clean gas
The solid ion exchanged film is used for this equipment
as the electrolyte for water electrolysis.Therefore,
pure water electrolysis is possible, without using a
strong alkaline electrolyte like conventional equipment.Antipollution
measures, such as alkali waste fluid processing, are
unnecessary entirely as well as clean gas being obtained
by that. |
 |
Easy operation
Only by turning switchON, the gas controlled by fixed
gas pressure is supplied immediately. |
 |
Maintenance-free
Since it is clean gas, there is no clogging of a pipe
or a nozzle, and periodical cleaning of a troublesome
electrolysis tub is also unnecessary. |
|
| Generation-of-gas
principle |
 |
Hydrogen
generating mechanism |
| Hydrogen and oxygen are
occurred by electrolysis of the water (refer
to the figure) by the electrochemistry cell
which made one an ion exchange membrane,
the anode and the cathode (with this equipment,
only hydrogen gas is utilized and oxygen
gas is emitted into the atmosphere.). The
amount of generation of gas is proportional
to the amount of electrolysis electricity,
and has the following relation. |
 |
| A
click familiarizes an expansion image
with looking. |
|
|
Per 1Ah
Hydrogen gas : 418cc (0°C.1013hPa,Theoretical
value)
Oxygen gas : 209cc (0°C.1013hPa,Theoretical
value) |
|
|
|
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
MO:
motor operate valve
LS: level sensor
CA: electric conductivity alarm
PA: pressure alarm
PI: pressure indicator
PIC: pressure indicator control
A click familiarizes an
expansion image with looking. |
|
|
 |
|
| Spec/Model |
HGU-100 |
HGU-200 |
HGU-1000 |
| The
kind of supply gas |
Hydrogen
(99.9% or more Except moisture) |
Hydrogen
(99.9% or more Except moisture) |
Hydrogen
(99.9% or more Except moisture) |
| The
maximum gas amount of supply (1/hr25 1013hPa) |
100 |
200 |
1000 |
| Standard
supply gas pressure (kPa) |
100 |
100 |
100 |
| Purified
water to use (μS/cm) |
0.2 or
less |
0.2 or
less |
0.2 or
less |
| The
amount of the maximum consumption of water(cc/hr , Theoretical
value) |
73.6 |
147.2 |
736 |
| Input
voltage |
1 200VAC
50/60Hz |
1 200VAC
50/60Hz |
3 200VAC
50/60Hz |
| Rating
input current (A) |
9 |
17 |
32 |
| Ambient
temperature for using (°C) |
5-30 |
5-30 |
5-30 |
| Size
of the equipment (mm) |
350W×750D×599H |
350W×750D×599H |
750W×1200D×1200H |
| Weight
of the equipment (kg) |
About60 |
About70 |
About400 |
| Cooling
water |
Unnecessary |
Unnecessary |
Necessary |
 |
 |
 |
 |
| Spec/Model |
HGU-2000 |
HGU-5000 |
| The
kind of supply gas |
Hydrogen
(99.9% or more Except moisture) |
Hydrogen
(99.9% or more Except moisture) |
| The
maximum gas amount of supply (1/hr25 1013hPa) |
2000 |
5000 |
| Standard
supply gas pressure (kPa) |
100 |
100 |
| Purified
water to use (μS/cm) |
0.2 or
less |
0.2 or
less |
| The
amount of the maximum consumption of water(cc/hr , Theoretical
value) |
1472 |
3680 |
| Input
voltage |
3 200VAC
50/60Hz |
3 200VAC
50/60Hz |
| Rating
input current (A) |
65 |
150 |
| Ambient
temperature for using (°C) |
5-30 |
5-30 |
| Size
of the equipment (mm) |
1000W×1200D×1407H |
1200W×1700D×1800H |
| Weight
of the equipment (kg) |
About1000 |
About1350 |
| Cooling
water |
Necessary |
Necessary |
 |
 |
 |
| It is possible to produce, and
inquire about capacity other than the series. |
 |
 |
 |
|
|
 |
 |
 |
 |
 |
for
both HGU-100/200
(HGU-2000 is not included
because it is a semi custom-made article.) |
| << A click familiarizes
an expansion image with looking. |
|
 |
|
| Catalog
Download |
|
 |
The files
are in Adobe Acrobat Format.
To view them you will need to download the
Adobe
Acrobat Reader |
|
|
 Those
who wish to have a Catalog need to click following
this picture. |
* The contents of our cataloges
may be changed without a preliminary announcement
by specification change of our products etc.
* Since you may be unable to purchase by the reason
of having already stopped production about our
product carried by our website, please approve
beforehand. |
|
|
|
|
|
|
 |
|
|  |